UNINTERRUPTIBLE POWER SUPPLY
|
|
 |
Introducing a new line of UPS systems with circuitry
- NEW! Hardwired models now available
- Models with individual outlet control
available
- Pure Sine Wave technology provides optimum waveform for sensitive AV components
- Line interactive with Automatic Voltage Regulation
- Compact rackmount chassis only 19” deep
- Easily integrates with control systems using RS-232 and analog I/O
- Total of 8 surge protected outlets
- Load shedding extends runtime for critical loads
- Expansion Battery Pack Option- Connect up to 10 to a single UPS for extended half-load runtimes of up to 20 hours
- Energy Saver circuitry- reduces power consumption by up to 75% when compared with traditional UPS designs
- Hot swappable primary battery for easy service
- 9’ SignalSAFE™ power cord minimizes stray magnetic fields
- Middle Atlantic Power Manager™ software allows the configuration of vital system settings
- 3 year warranty on electronics, 2 year warranty on batteries
Models with Web-Based Control are now available (UPS-1000R-IP/8IP and UPS-2200R-IP/8IP only)
- Real time UPS monitoring via the Web
- Remote management and configuration of UPS via Web Browser or NMS
- Auto-shutdown to protect servers/workstations from data lose due to power failure
- Schedule shutdown/start-up/reboot of the UPS
- Event logging to trace UPS operational history
- Data logging for analyzing power conditions
- Event notification via email and SNMP traps
- Supports TCP/IP, SNMP/HTTP, NTP, DNS, SMTP protocol
- MIB provided
- Quick installation and user friendly interface
- User upgradeable firmware via FTP
- Security management provided
- Other models, with a minimum firmware version of 1.65 can be upgraded using the UPS-IPCARD network interface card
#96_01101 Download
or view PDF file
#96_01160 Download
or view Hardwired UPS PDF file
|

UPS-1000R

UPS-EBPR Expansion Battery
|
|
| Front
|
|
| UPS-2200R-8IP
|
|
| Rear, Hardwired Model
|
| Part # |
Description |
Web Enabled |
Outlet Controlled |
Dimensions |
Rackspaces |
Termination |
| UPS-1000R |
1000VA / 750W UPS |
No |
Critical/Non-critical Bank |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-15P Plug |
| UPS-1000R-IP |
1000VA / 750W UPS |
Yes |
Critical/Non-critical Bank |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-15P Plug |
| UPS-1000R-8 |
1000VA / 750W UPS |
No |
Individual Outlet |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-15P Plug |
| UPS-1000R-8IP |
1000VA / 750W UPS |
Yes |
Individual Outlet |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-15P Plug |
| UPS-2200R |
2150VA / 1650W UPS |
No |
Critical/Non-critical Bank |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug |
| UPS-2200R-IP |
2150VA / 1650W UPS |
Yes |
Critical/Non-critical Bank |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug |
| UPS-2200R-8 |
2150VA / 1650W UPS |
No |
Individual Outlet |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug |
| UPS-2200R-8IP |
2150VA / 1650W UPS |
Yes |
Individual Outlet |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug |
| UPS-2200R-CH |
2150VA / 1650W UPS |
No |
Bank Control |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug input & hardwired output |
| UPS-2200R-CHIP |
2150VA / 1650W UPS |
Yes |
Bank Control |
17"W x 3.5"H x 19"D |
2 |
9’ cord w/NEMA 5-20P Plug input & hardwired output |
| UPS-2200R-HH |
2150VA / 1650W UPS |
No |
Bank Control |
17"W x 3.5"H x 19"D |
2 |
hardwired 36" flex cable input and hardwired output |
| UPS-2200R-HHIP |
2150VA / 1650W UPS |
Yes |
Bank Control |
17"W x 3.5"H x 19"D |
2 |
hardwired 36" flex cable input and hardwired output |
| UPS-EBPR |
UPS Expansion Battery Pack |
- |
- |
17"W x 3.5"H x 19"D |
2 |
|
| UPS-IPCARD |
UPS Network Interface Card* |
Yes |
- |
- |
- |
|
| UPS-RBP |
UPS Replacement Battery Pack |
- |
- |
- |
- |
|
*UPS-IPCARD is compatible with UPS Firmware v1.65 or greater. Important Note: Firmware version v 1.75 provides full functionality, v1.65 provides full functionality with the exception of non-critical bank control and non-critical bank scheduling.
|
|
|
|
Modules available from our control system partners:
|
|
|
Frequently Asked Questions:
Q: Can I control my Middle Atlantic UPS with a control system via the IP Card?
A: Not at this time. Control systems can be used to control the Middle Atlantic UPS via the RS232 port
Q: What is the maximum Wattage my Middle Atlantic UPS can handle?
A: For the UPS-1000R, 750 Watts is the maximum peak wattage. The recommended maximum continuous wattage is 600 Watts
For the UPS-2200R, 1650 Watts is the maximum peak wattage. The recommended maximum continuous wattage is 1320 Watts
Q: Why is there a difference between the VA and Wattage ratings?
A: VA (Volt Amps) is a simple arithmetic description; literally Volts x Amps. Power, expressed in Watts is Volts x Amps x Power Factor, which accounts for inefficiencies inherent in electrical equipment.
Q: Can I use my Middle Atlantic UPS on 208 or 240 Volt?
A: No. The UPS-1000R and UPS-2200R series are 120 Volt ONLY.
Q: How many expansion batteries can I add to my Middle Atlantic UPS?
A: Up to 10 UPS-EBPR expansion battery packs can be added to any Middle Atlantic UPS.
Q: What is the maximum run time I can get from Middle Atlantic UPS?
A: It depends on what the total load the Middle Atlantic UPS will be powering. The best way to determine which UPS and how many expansion batteries you may need is to determine your total backed up load in either Amps, VA, or Watts along with your desired run time and visit our UPS run time calculator at: http://www2.middleatlantic.com/UPS/Search.aspx.
|
|
|
|
|
|