DRK Series Rack, DRK19-44-42PROLRD
42" D X 83 1/2" H
Cage Nut Rail
Without Rear Door
MSRP
Loading Prices...
Qty
Add to Materials
Sorry! That combination does not exist.
Specifications
General Info
Gangable: Yes
Finish: Black Powder Coat
UL Standards Tested: UL1678
Listing Agencies/Third Party Certifications
ASCE: 7-10
OSHPD: 96-967
RoHS: Yes
Greenguard: Yes
UL Listing No: E173107
Dimensions
Usable Depth: 34.85
Usable Height: 77
Panel Width: 19
Capacity Weight (US): 10000
Depth (US): 42
Height (US): 83.485
Width (US): 30
Rack Units: 44
Technical Information
Rackrail Type: Cage Nut
Seismic Load Capacity: 755
Static Load Capacity: 10000
UL Load Capacity: 2500
Material: Steel
Mounting: Horizontal
ADDITIONAL INFORMATION
This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863.
LEED Contribution: Yes
RoHS_Compliant
LEED_Contribution
PepResources
EIA compliant 19” panel width equipment enclosure shall be Middle Atlantic Products model # DRK19-44-42PROLRD. Overall dimensions of enclosure shall be 83-1/2”H x 30”W x 42”D. Useable height shall be 44 rackspaces, useable depth shall be 34-3/4”. Fully welded construction shall provide a UL Listed 2,500 lb. weight capacity. Enclosure shall be constructed of the following materials: top and bottom shall be 14-gauge steel, horizontal braces shall be 1/8” thick steel, all structural elements shall be finished in durable black powder coat. Enclosure shall come equipped with 10” fan top and fan guard for ventilation, one pair of cable ducts with steel doors pre-installed in front of rack, two pairs of 11-gauge steel rackrail with 6mm cage nut mounting holes in universal EIA spacing, and finished in black e-coat with numbered rackspaces. Rack shall have a removable rear knockout panel with 1/2”, 3/4”, 1”, and 1-1/2” electrical knockouts installed in base, and removable split rear knockout panels with electrical knockouts and BNC knockouts for UHF/VHF antennae installed in top. Grounding and bonding studs shall be zinc plated 1/4-20x1 threaded, installed two each in base and top of enclosure. DRK Series enclosures shall satisfy the 2007 & 2010 CBC; 2006, 2009 & 2012 IBC; ASCE 7-05 (2005 Edition) & ASCE 7-10 (2010 Edition) and the 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity, Seismic Use Group III, Zone 4 or Seismic Design Category (SDC) “D” with lateral force requirements for protecting 755 lbs. of essential equipment in locations with the highest level of seismicity and top floor or rooftop installations with an Importance factor (Ip) of 1.5 when used with MRK-Z4 seismic floor anchor bracket. Rack shall be OSHPD approved for fixed equipment anchorage in California healthcare facilities. DRK shall be UL Listed in the US and Canada. DRK shall be GREENGUARD Indoor Air Quality Certified for Children and Schools. DRK enclosure shall be RoHS EU Directive 2011 / 65 / EU compliant. DRK shall be manufactured by an ISO 9001 and ISO 14001 registered company. Rack enclosure shall be warrantied to be free from defects in material or workmanship under normal use and conditions for the lifetime of the rack.
Resources